dc.descriptionTekanan darah dan denyut nadi merupakan hal yang sangat penting dalam bidang kesehatan khususnya di bidang Kedokteran. Terdapat dua macam kelainan tekanan darah, antara lain hipertensi atau tekanan darah tinggi dan hipotensi atau tekanan darah rendah. Hipertensi seringkali menjadi penyakit tidak menular nomor satu dibanyak Negara. Tensimeter adalah alat yang digunakan untuk mengukur tekanan darah. Tensimeter yang sering digunakan beberapa waktu yang lalu adalah tensimeter merkuri. Seiring dengan berkembangnya zaman, penggunaan tensimeter jenis ini telah dibatasi karena masalah lingkungan. Maka dari itu penulis merancang alat pengukur tekanan darah digital disertai dengan indikator tekanan darahnya, modul yang dibuat bersifat digital dan portable. Penggunaan tensimeter digital dinilai lebih praktis dan mudah. Pengujian dilakukan dengan cara membandingkan modul yang dibuat dengan sphygmomanometer aneroid yang telah terkalibrasi. Pengukuran tekanan dilakukan pada titik 40, 60, 80, 100 , 120, 140 dan 160 mmHg. Dari hasil pengujian, di dapatkan error maksimal yang dihasilkan sebesar 5,5 %. Kelemahan sensor menjadi pengaruh besar dalam error yang dihasilkan.en_US
dc.description.abstractBlood pressure and pulse have important role on health, particularly on medical field. There are two kinds of blood pressure disorder: hypertension and hypotension. Hypertension often becomes the most common non-communicable disease in many countries. Blood pressure monitor is a kind of equipment used to measure the blood pressure. For a long time, mercury blood pressure monitor is commonly used by people. However, these days, the use of this monitor is restricted because of environmental problem. Therefore, the writer designs a digital blood pressure monitor which has blood pressure indicator. The module is digital and portable. The use of digital blood pressure monitor is considered to be more practical and easy. The test was done by comparing the module and sphygmomanometer aneroid which has been calibrated. The measurement of the blood pressure is done on point 40, 60, 80, 100, 120, 140 and 160 mmHg. The result is that there is a maximal error for about 5.5%. The weakness of the sensor becomes the great influence on the resulted error.en_US
dc.publisherD3 UMYen_US
dc.subjectblood pressure, digital blood pressure monitor. : tekanan darah, tensimeter digitalen_US
dc.titleALAT PENGUKUR TEKANAN DARAH BERBASIS ATMEGA8 DILENGKAPI DENGAN INDIKATOR TEKANAN DARAHen_US
dc.typeThesis T A VOK 048en_US