Show simple item record

dc.contributor.authorFEBRIANTI, ADE NUR
dc.date.accessioned2018-07-09T06:07:26Z
dc.date.available2018-07-09T06:07:26Z
dc.date.issued2017-12-23
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/19973
dc.descriptionPengaruh utama kebisingan bagi manusia adalah kerusakan pada indera pendengaran yang dapat menyebabkan beberapa gangguan pendengaran mulai dari ketulian sementara maupun ketulian permanen bergantung pada intensitas, lama waktu dan kepekaan individu terhadap kebisingan tersebut. Deteksi dan penata laksanaan gangguan pendengaran baik pada anak maupun dewasa harus dilakukan sedini mungkin. Gangguan pendengaran pada orang dewasa akan menurunkan kualitas hidup, dimana penurunan pendengaran akan berdampak pada pekerjaan, proses belajar dan kehidupan sehari-hari. Pemeriksaan tingkat pendengaran manusia dapat menggunakan alat yang disebut audiometer. Penelitian ini bertujuan untuk membuat alat audiometer berbasis microcontroller ATMega 16. Komponen yang digunakan yaitu modul relay untuk equalizer, IC ATMega 16 untuk mengontrol sistem kerja keseluruhan. Alat ini dilengkapi dengan tampilan intensitas suara dan frekuensi. Microcontroller komponen utama yang mampu membangkitkan frekuensi 20 Hz, 120 Hz, 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2500 Hz, 4000 Hz, 8000 Hz, dan 15000 Hz, dengan intensitas suara (dB) yang dihasilkan 10-60 dB. Pengujian terhadap alat dilakukan dengan alat bantu oscilloscope digital dan smartphone android. Dari hasil pengujian didapatkan nilai error frekuensi alat dibawah 5% dan selisih terjauh nilai intensitas suara (dB) terjadi pada titik 40 dB yaitu sebesar 3 dB.en_US
dc.description.abstractThe major implication of noises on human is the damage in hearing sense that it causes hearing disorders, such as temporary or even permanent deaf, depending on how intense, how long and how sensitive each individual is exposed to the noises. Early detection and management of hearing disorders either towards children or adult are necessary to be conducted. Hearing disorders in adults would diminish their quality of life, in which such weakening hearing sense would have effect on work, study and daily life. Human hearing level can be checked by using audiometer. This research aims at building audiometer based on microcontroller ATMega 16. The components used were relay module for equalizer, IC ATMega 16 for controlling overall performance system. This tool is equipped with sound and frequency intensity interface. The main microcontroller component is able to generate frequency 20 Hz, 120 Hz, 125 Hz, 250 Hz, 500 Hz, 1000 Hz, 2500 Hz. 4000 Hz, 8000 Hz and 15000 Hz, with 10 – 60 dB sound intensity output. The tool testing was performed by using digital oscilloscope and android smartphone. The result of the testing shows that the tool’s error frequency is below 5 % and the highest sound intensity (dB) error margin is at 40 dB point, which is as many as 3 dBs.en_US
dc.publisherD3 UMYen_US
dc.subjectNoises, audiometer, microcontroller, frequency, sound intensity. Kebisingan, audiometer, microcontroller, frekuensi, intensitas suaraen_US
dc.titleRANCANG BANGUN AUDIOMETER BERBASIS MICROCONTROLLER ATMEGA 16en_US
dc.typeT A VOK 027en_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record