Show simple item record

dc.contributor.advisorWIJAYA, NUR HUDHA
dc.contributor.advisorSUKWONO, DJOKO
dc.contributor.authorHAKIM, ADNAN FAISHAL
dc.date.accessioned2018-10-04T03:11:14Z
dc.date.available2018-10-04T03:11:14Z
dc.date.issued2018-08-24
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/21705
dc.descriptionInfeksi Saluran kemih (ISK) merupakan suatu infeksi yang disebabkan oleh pertumbuhan mikroorganisme di dalam saluran kemih manusia. Gejala umum dari gangguan ISK dapat diketahui dari beberapa parameter, yaitu: kesulitan kencing, warna tidak normal, volume sedikit dan debit air kencing lambat, sehingga diperlukannya alat uroflowmetry untuk mengukur debit, kejernihan dan volume air kencing. Pada alat uroflowmetry ini, penulis menggunakan sensor YF-S201 dengan hasil output pulsa frekuensi yang nantinya di-convert menjadi mL/s, pengukuran volume menggunakan sensor HC SR04 pembacaan berupa nilai jarak yang di-convert menjadi mL, dan pengukuran kadar kejernihan air kencing menggunakan photo dioda. Dalam pengolahan data untuk dapat ditampilkan di display LCD penulis menggunakan ATMega8 sebagai pemproses microcontroller. Dengan hasil analisa tingkat error final volume pada gelas ukur didata 100 mL dan 200 mL mencapai 4%, 300 mL mencapai 3,1%, 400 mL mencapai 0,075% dan selisih tertinggi debit air kencing mencapai 3,3 mL/s. Setelah melakukan proses perencanaan, percobaan, pembuatan modul dan pengujian serta pendataan dapat disimpulkan bahwa bahwa alat “Uroflowmerty Dengan 3 Parameter (debit, kejernihan dan volume)” berfungsi dengan baik dan dapat digunakan untuk mendiagnosa ISK.en_US
dc.description.abstractUrinary Tract Infection is the kind of infection which is caused by microorganism growth in human’s urinary tract. The ordinary indication of urinary tract infection is known by some parameters, such as difficulty urinating, the abnormal of urine color, less volume and slow urinary discharge, that is why the writer need uroflowmetry tool to measuring the discharge, purity, and volume of urine. On this tool, in one side the writer use YF-S201 sensor with frequency pulse output and will be converted become Ml/s, volume measuring use HC SR04 sensor reading with converted distance value become mL, on the other hand urine purity measuring use diode photo. For operating the data in LCD display, the writer using ATMega8 as microcontroller processor. With the result of error final volume analysis in measuring cup is recorded 100 Ml and 200 ml reached 4%, 300 ml reached 3,1%, 400 Ml reached 0,075% and the highest difference of urine discharge reached 3,3 ml/s. After did the module experiment and testing also data collection, it could be concluded that uroflowmerty tool by 3 parameters (discharge, purity and volume)” works success and could be used for urinary tract infection diagnosis.en_US
dc.publisherPROGRAM VOKASI UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectISK, Debit, Volume, Clarityen_US
dc.titleUROFLOWMETRY DENGAN 3 PARAMETER (DEBIT, KEJERNIHAN DAN VOLUME)en_US
dc.typeThesis SKR VOK 055en_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record