dc.descriptionDalam bidang kedokteran gigi saat ini memerlukan teknologi modern untuk dapat menunjang kinerja dari dokter gigi. Sampai saat ini untuk mengukur maloklusi Overbite dan Overjet dilakukan secara manual, yaitu dengan membuat model gigi tiruan dengan bahan alginat dan di ukur dengan didital caliper. Hal ini tentu saja kurang efektif bagi dokter gigi karena memakan waktu dan memerlukan ketelitian di setiap pengukuranya. melihat latar belakang tersebut penulis bermaksud untuk membuat Rancang bangun alat ukur maloklusi overbite dan overjet untuk mempermudah kinerja dokter gigi. Alat ini dirancang menggunakan sensor Flex yang mendeteksi kelengkungan sudut yang terjadi karena gaya gigit dan ATmega328 sebagai pengolah data. Dalam pengujian alat penulis membandingkan hasil dari prototype dengan melakukan pengukuran manual menggunakan didital caliper agar dapat diketahui nilai errornya. Berdasarkan pengujian alat, diperoleh hasil bahwa prototype ini bekerja dengan baik dan memiliki nilai error 0,01 % untuk pengukuran Overbite serta memiliki nilai error 0,02% untuk pengukuran Overjet.en_US
dc.description.abstractRecently, dentistry needs modern technology to be able to support dentist’s performance. Until now, measuring the overbite and overjet malocclusion is done manually, i.e. by making denture model with alginate material, and is measured with digital caliper. This is, of course, less effective for dentist because it takes time and needs accuracy in its every measurement. Considering the background, the researchers tried to make the design for measurement tool of overbite and overjet malocclusion to make the dentist’s performance easier. This tool was designed using Flex censor that detected angular curvature caused by bite style and ATmega328 as data processor. In the tool testing, the researchers compared the result of the prototype by conducting manual measurement by using digital caliper in order to find the error value. Based on the tool testing, the result was that prototype worked well and had value error of 0.01% to measure overbite. Meanwhile, the error value for overjet measurement was 0.02%.en_US
dc.publisherPROGRAM VOKASI UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectMalocclusion, Overbite, Overjet, Digital Caliper, Flex Censor, ATmega328, Microcontroller.en_US
dc.titleRANCANG BANGUN ALAT UKUR MALOKLUSI OVERBITE DAN OVERJETen_US
dc.typeThesis SKR VOK 087en_US