dc.descriptionPeraturan pembebanan gempa di Indonesia yang hingga saat ini digunakan, menyediakan dua metode pendekatan untuk menganalisis respons struktur akibat gempa yaitu metode ekivalen statik dan dinamik (respon spektrum dan time history) dimana metode ekivalen statik hanya dikhususkan untuk struktur yang relatif sederhana dan tidak direkomendasikan untuk struktur bertingkat tinggi sehingga untuk mengatasi keterbatasan tersebut dibutuhkan analisis secara dinamik. Pengaruh gaya lateral akibat gempa, juga dapat menyebabkan deformasi yang besar pada struktur gedung bertingkat tinggi, sehingga beban statik pada struktur yang terdistribusi menjadi gaya aksial pada kolom, akan memberikan pengaruh gaya tambahan yaitu pengaruh non-linier geometri (efek P-delta). Untuk itulah akan dilakukan sebuah penelitian tentang perbandingan respons struktur baja pada tipikal bangunan gedung bertingkat dengan model portal 2D terhadap gaya lateral gempa dengan metode ekivalen statik dan time history serta pengaruh efek P-delta yang dianalisis dengan bantuan program SAP2000 V14.2.1 terhadap stabilitas struktur baja dan sambungan (end-plate) baja melalui variasi jumlah tingkat yaitu 7, 9, 10 dan 15 tingkat. Dari hasil penelitian, disimpulkan bahwa metode statik ekivalen dapat digunakan pada model struktur 7 dan 9 tingkat karena memberikan hasil yang lebih besar dari metode dinamik time history. Akan tetapi, untuk model struktur 10 dan 15 tingkat, metode time history lebih direkomendasi karena memberikan hasil yang lebih besar sehingga dinilai lebih aman. Jika ditinjau dari pengaruh efek P-delta, struktur 7 tingkat memberikan hasil yang besar karena jarak antar kolom yang direncanakan relatif jauh. Hal ini menyebabkan beban yang terdistribusi pada kolom menjadi cukup besar sehingga ketika struktur berdeformasi akibat gaya lateral, pengaruh gaya tambahan akibat gaya aksial pada kolom akan mengalami peningkatan yang cukup besar. Model struktur 15 tingkat juga memberikan efek P-delta yang besar. Hal ini karena gaya aksial pada kolom yang menyebabkan efek P-delta, didasarkan pada distribusi beban struktur yang besar akibat tingkat gedung yang relatif tinggi. Pada model struktur 9 dan 10 tingkat, pengaruh efek P-delta yang terjadi tidak dominan besar sehingga dapat diabaikan.en_US
dc.description.abstractThe standard for earthquake resistance regulations in Indonesia which until now have been used, provide two approaches to analyzing structural responses due to earthquakes, namely static equivalent method and dynamic methods (spectrum response and time history) where static equivalent methods are only specific to relatively simple structures and are not recommended for structures high-rise so that to overcome these limitations requires dynamic analysis. The influence of lateral forces due to earthquakes can also cause large deformations in the structure of high-rise buildings, so that the static load in structures distributed into axial forces in the column will provide additional force effects, namely the influence of non-linear geometry (P-delta effect). For this reason, a study of the comparison of steel structure responses to typical multi-storey buildings with 2D portal models to the lateral earthquake force with static equivalent method and time history and the effect of P-delta effects were analyzed with the help of SAP2000 V14.2.1 program on the stability of steel structures and steel end-plates through variations in the number of levels, namely 7, 9, 10 and 15 levels. From the results of the study, it was concluded that the equivalent static method can be used in the structure model 7 and 9 levels because it gives results greater than the dynamic time history method. However, for the 10 and 15 level structure models, the time history method is recommended because it provides greater results so that it is considered safer. If viewed from the effect of the P-delta effect, the 7-level structure gives great results because the planned distance between columns is relatively far. This causes the distributed load in the column to be quite large so that when the structure is deformed due to lateral forces, the effect of additional forces due to axial forces in the column will experience a considerable increase. The 15-level structure model also provides a large P-delta effect. This is because the axial force in the column which causes the P-delta effect, is based on a large structural load distribution due to the relatively high level of the building. In the 9 and 10 level structure models, the effect of the P-delta effect that occurs is not so dominant that it can be ignored.en_US
dc.publisherFAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectearthquake, static equivalent, time history, spectrum response, P-delta, column capacity, steel connection (end-plate)en_US
dc.titleEVALUASI PERBANDINGAN PEMBEBANAN GEMPA PADA GEDUNG BERTINGKAT SERTA PENGARUH EFEK P-DELTA TERHADAP STABILITAS STRUKTUR BAJAen_US
dc.title.alternativeStudi Kasus : Model Portal 2D 7, 9, 10 Dan 15 Lantaien_US