dc.descriptionIsolasi pada transformator merupakan salah satu komponen yang sangat penting. Sehingga kualitas tahanan pada isolasi transformator sangat perlu diperhatikan kondisinya. Untuk mengetahui kondisi dari isolasi transformator harus melakukan beberapa pengujian yaitu indeks poalarisasi, tangen delta dan break down voltage. Pada penulisan tugas akhir ini, ketiga pengujian tersebut dilakukan pada Trafo 1 di Gardu Induk 150 kV Bantul . Pengujian indeks polarisasi sendiri merupakan pengujian arus bocor pada isolasi transformator dengan membandingkan hasil uji selama 1 menit dengan hasil uji selam 10 menit. Sementara tangen delta merupakan pengujian arus bocor kapasitif pada isolasi trasnformator. Dan break down voltage merupakan pengujian kemampuan tegangan tembus pada minyak isolasi transformator. Berdasarkan hasil analisis dapat diketahui nilai indeks polarisasi transformator pada tahun 2016 dan tahun 2018 rata-rata nilai antar belitannya sudah berada di rating 1,25-2,0. Sementara untuk hasil uji tangen delta pada tahun 2016 dan tahun 2018 nilai antar bagian kapasitif nya sudah berada di rating 0,18%-0,36%. Dan untuk hasil uji break down voltage pada tahun 2016 dan tahun 2018 rata-rata nilai tegangan tembusnya 43,9 kV/mm-65,5 kV/mm. Dari data tersebut dapat disimpulkan bahwa kondisi isolasi transformator pada tahun 2016 dan 2018 dalam keadaan baik. Walaupun terjadi di penurunan kondisi isolasi transformator pada tahun 2016. Namun pihak PLN sudah melakukan perbaikan dan pemeliharaan terhadapa isolasi trasnformatornya. Ini terlihat karena adanya peningkatan kualitas isolasi transformator pada tahun 2018. Perbaikan dan pemeliharaan isolasi transformator ini dilakukan untuk memaksimalkan sistem kerja dan umur dari transformator.en_US
dc.description.abstractInsulation on the transformer is a very important component. So that the quality of the prisoner in the transformer insulation is very important. To find out the condition of the isolation transformer must do some testing, namely poalarization index, delta tangent and break down voltage. At the writing of this thesis, the three tests were carried out at Transformer 1 at the 150 kV Substation of Bantul. Polarization index testing itself is a test of leakage current in the transformer insulation by comparing the test results for 1 minute with 10 minutes diving test results. While the tangent delta is a test of capacitive leakage current on the transformer isolation. And break down voltage is a test of the breakdown voltage capability in transformer insulation oil. Based on the results of the analysis, it can be seen that the transformer polarization index value in 2016 and 2018 has an average rating between 1.25-2.0. While for the delta tangent test results in 2016 and 2018 the value between the capacitive parts is already at a rating of 0.18% -0.36%. And for the break down voltage test results in 2016 and 2018 the average breakdown voltage is 43.9 kV / mm-65.5 kV / mm. From these data it can be concluded that the conditions of transformer isolation in 2016 and 2018 are in good condition. Although there was a decline in the condition of transformer insulation in 2016. However, the PLN has made repairs and maintenance of the transformer isolation. This is seen because of the increase in the quality of the transformer insulation in 2018. The repair and maintenance of the transformer insulation is done to maximize the working system and the life of the transformer.en_US
dc.publisherFAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectTransformer, Insulation Resistance, Polarization Index, Tangen Delta, Break Down Voltage.en_US
dc.titleANALISIS TAHANAN ISOLASI TRANSFORMATOR DI GARDU INDUK 150 KV BANTUL BERDASARKAN HASIL UJI INDEKS POLARISASI, TANGEN DELTA DAN BREAK DOWN VOLTAGEen_US
dc.typeThesisen_US