dc.description | Gedung Ramai Mall Yogyakarta salah satu gedung yang menggunakan
suplai energi listrik dari PLN. Akan tetapi suplai energi listrik dari PLN tidak
mampu secara terus-menerus menyediakan energi listrik tanpa adanya gangguan.
Sehingga, untuk mengantisipasi hal tersebut maka perlu adanya sistem back-up
energi listrik berupa generator set (Genset) agar energi listrik tetap terjaga untuk
kebutuhan gedung. Genset bekerja secara otomatis, sehingga pada saat energi PLN
padam maka genset akan langsung bekerja. Begitupun sebaliknya, apabila energi
listrik PLN normal kembali, maka genset akan berhenti bekerja.
Karena sistem back-up energi listrik gedung Ramai Mall Yogyakarta sudah
bekerja cukup lama, maka perlu adanya evaluasi dan analisa kembali sistem backup
gedung untuk menunjang keandalan sistem. Analisa dilakukan dengan
melakukan perhitungan dibantu dengan program simulasi ETAP 12.6.0. dari hasil
perhitungan, komponen sistem genset gedung masih sesuai dengan acuan PUIL
2000. Akan tetapi, untuk efisiensi genset gedung terbilang rendah yaitu 48,9 %
dikarenakan pembebanan genset yang rendah. Dari hasil simulasi, beban yang harus
di suplai genset sebesar 865 kVA dan kapasitas genset yang digunakan sebesar
1000 kVA. Dalam hal ini, kinerja genset masih dalam batas kemampuan. | en_US |
dc.description.abstract | The Ramai Mall Yogyakarta is one of building which is using the electric
source from PLN. However, the electric source from PLN cannot supply
continuously without several problems. Therefore, in order to anticipate those
problems, we need a backup system as a generator set to keep on the electric energy
of the building. Generator set works automatically, when the electric source from
PLN cannot be used, the generator set turn on automatically. Then, when the
electric source from PLN can be accessed, the generator set turn off automatically.
Because of the backup system in The Ramai Mall Yogyakarta had worked
for a long time, we need to evaluate and reanalyze the backup system of the building
in order to make the system run well. The analyzing of the system applies
quantitative approach and it is supported with ETAP I2, 6. 0. Simulation Program
which simulates from the result of calculation, the components of the backup system
is suitable with PUIL 2000 requirements. However, the efficient degree of the
generator set of the building is low 48, 5% because the loading of the generator set
is low. According to the result of simulation, the loading which have to be supplied
by generator set is 865 kVA and the capacity which is used by generator set is 1000
kVA. In this case, the generator set works in its ability. | en_US |
dc.publisher | FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH YOGYAKARTA | en_US |
dc.subject | generator backup system, PUIL, installation of electric energy | en_US |
dc.title | UNJUK KERJA GENERATOR SET (GENSET) SEBAGAI BACK UP DAYA ENERGI LISTRIK PADA GEDUNG RAMAI MALL YOGYAKARTA | en_US |