dc.description | Pemanas air tenaga surya (PATS) adalah salah satu aplikasi teknologi
yang berfungsi untuk menghasilkan air panas guna memenuhi kebutuhan rumah
tangga maupun industri. Pada umumnya instalasi PATS diletakkan di luar
ruangan (outdoor) dengan memanfaatkan sumber energi dari matahari. Metode ini
memiliki kelemahan dalam menyelidiki pengaruh besarnya energi input
dikarenakan intensitas radiasi matahari berubah-ubah setiap waktu sehinggga
menyebabkan penyerapan kalor oleh heat transfer fluid (HTF) dan phase change
material (PCM) pada PATS berfluktuasi. Oleh karena itu, perlu dilakukan
penelitian di dalam ruangan (indoor) dengan memberikan heat flux yang dapat
divariasikan sehingga dapat mengetahui pengaruh variasi heat fux terhadap
karakteristik efisiensi termal pada kolektor.
Penelitian secara indoor dilakukan dengan menggunakan solar simulator
yang berfungsi sebagai sumber kalor yang dapat dikontrol. Solar simulator
diletakkan pada bagian atas kolektor. Termokopel dipasang pada bagian HTF dan
PCM. Pembacaan temperatur pada termokopel digunakan data logger temperatur
dan software pada personal computer (PC) dan laptop. Variasi heat flux yang
digunakan sebesar 800, 1000, dan 1200 W/m2. Proses pemanasan air dilakukan
selama 98 menit menggunakan debit 2 LPM. Data temperatur air yang ada di
dalam tangki di rekam. Pengujian diulang dengan mengubah variasi heat flux.
Analisis data dilakukan untuk mengetahui efisiensi termal pada kolektor.
Hasil penelitian dari tiap pengujian menunjukkan bahwa adanya pengaruh
pemberian variasi heat flux terhadap besar kecilnya efisiensi termal yang
diperoleh kolektor. Semakin tinggi variasi heat flux yang diberikan, efisiensi
termal kolektor semakin rendah, begitupun sebaliknya | en_US |
dc.description.abstract | Solar water heater (PATS) is one of the technology applications that
serves to produce hot water to meet the needs of households and industries. In
general, PATS installation is placed outdoors (outdoor) by utilizing the source of
energy from the sun. This method has a weakness in investigating the influence of
the magnitude of input energy because the intensity of the sun radiation fluctuates
every time until it causes the absorption of the heat transfer fluid (HTF) and
phase change material (PCM) on PATS Fluctuate. Therefore, it is necessary to do
indoor research by providing the heat flux that can be varied so as to know the
influence of heat Fux variation on thermal efficiency characteristics in collectors.
Indoor research is do using a solar simulator that serves as a controllable
heat source. Solar Simulator is placed on the top of the collector. Thermocouples
are installed on the HTF and PCM parts. Temperature readings on
thermocouples are used in temperature logger data and software on personal
computer (PC) and laptop. Heat flux variations used are 800, 1000, and 1200
W/m2. The water heating process is carried out for 98 minutes using 2 LPM
discharge. The water temperature Data in the tank is recorded. Testing is
repeated by changing the heat flux variation. Data analysis is conducted to
determine the thermal efficiency of collectors.
The research results of each test show that there is a influence of the heat
flux variation on the small thermal efficiency obtained by the collector. The
higher the heat flux variation is given, the thermal efficiency of the collector is
getting lower, likewise vice versa | en_US |