Show simple item record

dc.contributor.authorSUKAMTA, SUKAMTA
dc.date.accessioned2020-03-02T05:15:27Z
dc.date.available2020-03-02T05:15:27Z
dc.date.issued2012-04
dc.identifier.issn2231-1424
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/32190
dc.description.abstractThe objective of the research is to investigate the heat transfer profiles by using a measurement of the temperature distributions during condensation in a horizontal annulus pipe. The circumferential temperature distribution along the annulus pipe wall were measured in order to investigate the heat transfer characteristics around the annulus pipe. An annulus pipe with inner section test pipe made from copper material (din = 17.2mm, do = 19mm) with a length of 1.8m and outer section test pipe made from a Galvanized Iron Pipe (din = 108.3mm, do = 114.3mm) with a length of 1.6m covered by 10 mm thick insulation was used in this experiment.en_US
dc.subjectheat transfer coefficienten_US
dc.subjectsteam condensaen_US
dc.subjectannulus pipe.en_US
dc.titleEXPERIMENTAL INVESTIGATION ON THE LOCAL PROFILES OF HEAT TRANSFER COEFFICIENT DURING THE STEAM CONDENSATIION IN A HORIZONTAL ANNULUS PIPEen_US
dc.typeOtheren_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • JURNAL
    Berisi tulisan dosen dalam yang telah dimuat dalam jurnal nasional maupun internasional yang tidak diterbitkan oleh UMY. Diharapkan menambahkan link dari jurnal yang asli dalam diskripsinya.maupun internasional

Show simple item record