dc.contributor.advisor | SYAHPUTRA, RAMADHONI | |
dc.contributor.advisor | MUSTAR, MUHAMMAD YUSVIN | |
dc.contributor.author | HARTONO, RUDI | |
dc.date.accessioned | 2016-12-16T01:34:25Z | |
dc.date.available | 2016-12-16T01:34:25Z | |
dc.date.issued | 2016-08-30 | |
dc.identifier.uri | http://repository.umy.ac.id/handle/123456789/7243 | |
dc.description | The electrical system is a three-phase electrical systems that have 3 pieces symmetrical output and has the distinction of each phase angle of 120o. In a series of three-phase, there are two kinds of relationships the star circuit and delta circuit. The series of three-phase star circuit using the wire 3 wire 3 phase, while in the circuit of 3 phase 4 wire circuit using the Star, 3-phase and 1 wire to wire to neutral. Neutral current in the circuit is a circuit star circuit point between the third phase. 3 phase system itself is typically used in industries, because the industry itself uses 3-phase power. In contrast to households using electric power 1-phase.
This thesis resulted in a current and voltage monitoring tool. Parameters monitored include voltage, current, active power, reactive power and power factor on each phase at the load side. Current and voltage monitoring tool using a current sensor and a voltage sensor SCT 013-000 ZMPT101B as the measuring sensor | en_US |
dc.description.abstract | The electrical system is a three-phase electrical systems that have 3 pieces symmetrical output and has the distinction of each phase angle of 120o. In a series of three-phase, there are two kinds of relationships the star circuit and delta circuit. The series of three-phase star circuit using the wire 3 wire 3 phase, while in the circuit of 3 phase 4 wire circuit using the Star, 3-phase and 1 wire to wire to neutral. Neutral current in the circuit is a circuit star circuit point between the third phase. 3 phase system itself is typically used in industries, because the industry itself uses 3-phase power. In contrast to households using electric power 1-phase.
This thesis resulted in a current and voltage monitoring tool. Parameters monitored include voltage, current, active power, reactive power and power factor on each phase at the load side. Current and voltage monitoring tool using a current sensor and a voltage sensor SCT 013-000 ZMPT101B as the measuring sensor | en_US |
dc.publisher | FT UMY | en_US |
dc.subject | electric power supply system, SCT 013-000, ZMPT101B. | en_US |
dc.title | RANCANG BANGUN SISTEM MONITORING ARUS DAN TEGANGAN PADA SISTEM TENAGA LISTRIK TIGA FASA BERBASIS LAB VIEW | en_US |
dc.type | Thesis
SKR
340 | en_US |