dc.contributor.author | KISMAWAN, ARWAN WAWANG | |
dc.date.accessioned | 2017-09-25T03:03:14Z | |
dc.date.available | 2017-09-25T03:03:14Z | |
dc.date.issued | 2017-06-17 | |
dc.identifier.uri | http://repository.umy.ac.id/handle/123456789/15036 | |
dc.description | Pemanas air tenaga surya (PATS) adalah alat pemanasan air yang sumber energinya berasal dari matahari. PATS yang menggunakan air sebagai penyimpan kalor memiliki kekurangan yaitu densitas energinya rendah. Salah satu cara untuk meningkatkan densitas energi adalah dengan mengaplikasikan sistem penyimpanan energi jenis sensibel (sensibel heat storage, SHS) dengan (laten heat storage, LHS) dimana densitas energinya tinggi. Penelitian terakhir tentang aplikasi paraffin wax sebagai media penyimpan energi termal pada PATS thermosyphon belum membahas tentang stratifikasi. Penelitian ini menarik untuk dikembangkan dalam hal volume penyimpanan energinya diperbesar dan perlunya investigasi tentang stratifikasi termal yang terjadi. Tujuan penelitian ini adalah mengkaji secara eksperimental stratifikasi termal di dalam tangki pada sistem PATS thermosyphon yang berisi PCM (phase change material) selama proses charging.
Penelitian ini dimulai dengan memposisikan PATS pada ruang outdoor serta menutup kolektor dan mengisi air pada tangki. Pengumpulan data dilakukan dengan pengambilan data intensitas radiasi matahari, PCM dan HTF (heat transfer fluid) selama proses charging. Olah data dan analisis dimulai dengan memplot grafik intensitas radiasi matahari dan temperatur udara luar serta grafik HTF dan PCM selama proses charging. Stratifikasi termal yang terjadi dilakukan dengan perhitungan bilangan Richardson.
Stratifikasi termal telah terbentuk di dalam tangki PATS selama proses charging. Keadaan ini terlihat secara visual berdasar grafik evolusi HTF dimana air yang berada di bawah, temperaturnya lebih rendah. Stratifikasi yang terjadi juga terindikasi oleh bilangan Richardson sebesar 2,36 pada akhir proses charging. | en_US |
dc.description.abstract | Solar water heater (PATS) is a water heating device whose source of energy comes from the sun. PATs that use water as heat stores have a deficiency of low energy density. One way to increase energy density is by applying a sensible heat storage (SHS) storage system with latent heat storage (LHS) where the energy density is high. Recent research on paraffin wax applications as thermal energy storage media in PATS thermosyphon has not discussed about stratification. This research is interesting to develop in terms of enlarged energy storage volume and the need for an investigation of the thermal stratification that occurs. The purpose of this study is to experimentally review the thermal stratification in the tank on a PATS thermosyphon system containing PCM (phase change material) during the charging process.
This research begins by positioning PATS in the outdor room and closing the collector and filling the water in the tank. Data collection is done by taking data of radiation intensity of sun, PCM and HTF (heat transfer fluid) during charging process. The data and analysis exercise begins by plotting the graph of the intensity of solar radiation and outside air temperature as well as the HTF and PCM graphs during the charging process. The thermal stratification is done by calculating the Richardson number.
Thermal stratification has been formed in the PATS tank during the charging process. This situation is visually visible on a graph of HTF evolution where the water is below, the temperature is lower. Stratification is also indicated by Richardson number of 2.36 at the end of the charging process. | en_US |
dc.publisher | FT UMY | en_US |
dc.subject | PATS, PCM, HTF, thermosyphon and thermal stratification. PATS, PCM, HTF, thermosyphon dan stratifikasi termal | en_US |
dc.title | KAJIAN EKSPERIMENTAL STRATIFIKASI TERMAL PADA PEMANAS AIR TENAGA SURYA THERMOSYPHON BERISI PHASE CHANGE MATERIAL | en_US |
dc.type | Thesis
SKR
F T
438 | en_US |