      ANALISIS KEANDALAN JARINGAN DISTRIBUSI RAYON KOTA PALU DENGAN MEMPERTIMBANGKAN INTEGRASI PEMBANGKIT TERSEBAR ENERGI TERBARUKAN

      Thumbnail
      View/Open
      COVER (98.44Kb)
      HALAMAN JUDUL (545.8Kb)
      PENGESAHAN (386.4Kb)
      ABSTRAK (182.7Kb)
      BAB I (95.31Kb)
      BAB II (528.5Kb)
      BAB III (171.4Kb)
      BAB IV (1.038Mb)
      BAB V (86.50Kb)
      DAFTAR PUSTAKA (183.6Kb)
      LAMPIRAN (989.4Kb)
      NASKAH PUBLIKASI (500.2Kb)
      Date
      2017-12-13
      Author
      KURNIAH LALISU, MUHAMMAD DWI
      Metadata
      Show full item record
      Abstract
      Reliability network distribution is an important factor in continuity of service and distribution of electricity. There are parameters used to understand the quality of electricity distribution in which distributed by network distribution, the parameters are SAIFI (System Average Interuption Frequency Index), and SAIDI (System Average Interuption Duration Index). Afterward, there are standards that used to become comparasion parameter, the standards are SPLN 68-2 1986, IEEE std 1366-2003, dan WCC (World Class Company) & WCS (World Class Service). Distributed generation is a generator implied that integrated to load area, distributed generation that will be integrated is wind turbine in which it will be installed on express 3 feeder, Electrical Transient Analyzer Program (ETAP) used to help on the process of analysis and also calculation. Based on calculation and analysis on reliability of Kota Palu district that has been obtained, the reliability relatively unreliable, because of the majority feeders’ index reliability incompatible with the standard, and the effective velocity of wind used to generate power in distributed generation is 9,24 m/s.
      URI
      http://repository.umy.ac.id/handle/123456789/16866
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV