      ANALISIS PERFORMA ELECTROSTATIC PRECIPITATOR SEBAGAI PENGENDALI FLY ASH DAN PEMANFATAN LIMBAH B3 PADA BOILER DI PLTU SURALAYA

      Thumbnail
      View/Open
      COVER (100.5Kb)
      HALAMAN JUDUL (718.1Kb)
      HALAMAN PENGESAHAN (299.7Kb)
      INTISARI (84.49Kb)
      BAB I (171.4Kb)
      BAB II (2.544Mb)
      BAB III (100.6Kb)
      BAB IV (394.1Kb)
      BAB V (86.22Kb)
      DAFTAR PUSTAKA (65.14Kb)
      LAMPIRAN (3.923Mb)
      Date
      2018-05-21
      Author
      APRILLIANTO, FAJRIAH TOMMY
      Metadata
      Show full item record
      Abstract
      The amount of fuel emissions in the form of exhaust gases and particulate burning results in boiler recovery against the air pollution it produces is a serious problem to solve. The purpose of this study is to find out how much exhaust emissions produced by a boiler recovery and engineering use of electrostatic precipitator (ESP) so that exhaust emissions and particulate matter can be reduced. The steps taken in this research is to calculate mathematically the capacity of exhaust gas released by boiler recovery (m3 / hr) and analyze the flue gas data on ESP that does not work in one of the recovery boilers. The results obtained on the calculation of SCA (specific area area) on ESP Recovery Boiler with normal working condition is 19,87 m2 per 1000 m3 / h, whereas if one ESP does not work, its SCA value is 14,9 m2 per 1000 m3 / h. Both under normal conditions and ESP conditions are not working, the SCA values are still within the ESP design range of 11 - 45 m2 per 1000 m3 / h, to produce more than 99% efficiency.
      URI
      http://repository.umy.ac.id/handle/123456789/19388
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV