      EVALUASI KEANDALAN JARINGAN DISTRIBUSI 20 KV BERDASARKAN FREKUENSI GANGGUAN DI PT. PLN (persero) RAYON SEDAYU

      Thumbnail
      View/Open
      COVER (197.0Kb)
      HALAMAN JUDUL (1.831Mb)
      HALAMAN PENGESAHAN (689.7Kb)
      INTISARI DAN ABSTRAK (284.4Kb)
      BAB I (279.8Kb)
      BAB II (1.015Mb)
      BAB III (299.8Kb)
      BAB IV (1.643Mb)
      BAB V (274.9Kb)
      DAFTAR PUSTAKA (273.7Kb)
      LAMPIRAN (249.4Kb)
      NASKAH PUBLIKASI (616.2Kb)
      Date
      2018-08-15
      Author
      SUKMA, ADITYA GUNADI
      Metadata
      Show full item record
      Abstract
      The need for electrical energy nowadays increases as the growth of population, economy and industry. It should be supported by a reliable and continuous distribution system of human resources. Therefore, it is required an electric power system that has quality in accordance with the standards set by PT. PLN. This research aims to know the distribution of 20 kV system in every feeder at PT. PLN (Persero) Rayon Sedayu using SAIFI, SAIDI, ENS and AENS calculation index based on the monitoring data of power outage that has been occurring since 2017. Results obtained by the distribution system of Rayon Sedayu in 2017 if it is evaluated by SPLN 68-2 1986 standard is the values of SAIFI and SAIDI are two non-standard feeders, those are GDN 01 and GDN 04 feeder, while the other connection has met the standard. Beside that, when it is evaluated by IEEE std 1366-2003 standard, the values of SAIFI and SAIDI are four non-standard out of seven Rayon Sedayu feeders. Those are GDN 01, GDN 03, GDN 04 and GDN 05 feeder. If it is evaluated by ENS and AENS calculations, there will be an energy loss in every Rayo Sedayu feeders that are not channeled due to the power outages in the distribution network.
      URI
      http://repository.umy.ac.id/handle/123456789/21333
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV