View Item 
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Medicine and Health Science
      • Department of Dentistry
      • View Item
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Medicine and Health Science
      • Department of Dentistry
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      PERBANDINGAN AKURASI HASIL RADIOGRAFI KONVENSIONAL DAN COMPUTED RADIOGRAPHY (CR) PADA TEKNIK BITEWING UNTUK MENDETEKSI KARIES PROKSIMAL BUATAN

      Thumbnail
      View/Open
      COVER (32.71Kb)
      HALAMAN JUDUL (2.367Mb)
      HALAMAN PENGESAHAN (2.049Mb)
      ABSTRAK (95.63Kb)
      BAB I (246.3Kb)
      BAB II (255.0Kb)
      BAB III (221.3Kb)
      BAB IV (109.8Kb)
      BAB V (84.90Kb)
      DAFTAR PUSTAKA (94.31Kb)
      LAMPIRAN (850.6Kb)
      NASKAH PUBLIKASI (127.8Kb)
      Date
      2018-08-21
      Author
      AZHASITA, SHASHA
      Metadata
      Show full item record
      Abstract
      Background: Proximal caries is a caries that formed between one to another teeth and often can not be detected visually or with the help of explorer, so it is necessary to do radiography examination. Radiographic examination to detect caries is using bitewing techniques. Conventional radiography uses image receptors in the form of films that require a dark room in the process, using chemicals and difficult in storage or distribution. Computed radiography uses photostimulable phospor imaging plates which eliminate disadvanteges of conventional radiography and also reduce the dose of radiation received by patients. Aims: To know the is different in the accuracy results in conventional radiography and CR using bitewing techniques for artificial proximal caries detection. Method: This research used analytic observational method with cross-sectional design. Samples in the form of 40 premolar that prepared using round burs on the mesial part 1 mm deep as a simulation of proximal caries. The sample is then planted in a cast model and fixed using plasticine. Each cast model was planted with 2 maxillary premolars and 2 in mandible. The cast model is then x-rayed with conventional radiography and CR. X-rays are then seen in the viewer for interpretation of whether artificial proximal caries that have been made are seen or not. Result: Conventional radiography can detect 33 artificial proximal caries, in contrary, CR can detect 35 artificial proximal caries. The Chi-square statistic test results stated that the difference was not significant. Conclusion: There is no significant difference in accuracy between the results of conventional radiography and CR in bitewing techniques to detect artificial proximal caries.
      URI
      http://repository.umy.ac.id/handle/123456789/21970
      Collections
      • Department of Dentistry

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV