      PENYEIMBANGAN BEBAN PADA TRANSFORMATOR DISTRIBUSI UNTUK MENEKAN RUGI-RUGI DAYA PADA JARINGAN TEGANGAN RENDAH DI PT. PLN (PERSERO) RAYON SEDAYU

      Thumbnail
      View/Open
      COVER (46.54Kb)
      HALAMAN JUDUL (658.0Kb)
      HALAMAN PENGESAHAN (559.2Kb)
      ABSTRAK (18.23Kb)
      BAB I (148.8Kb)
      BAB II (618.2Kb)
      BAB III (25.16Kb)
      BAB IV (396.9Kb)
      BAB V (8.892Kb)
      DAFTAR PUSTAKA (229.6Kb)
      LAMPIRAN (287.5Kb)
      NASKAH PUBLIKASI (553.4Kb)
      Date
      2019-07-23
      Author
      FADLI, ILHAM
      Metadata
      Show full item record
      Abstract
      The unbalanced load in electric power distribution system always happens and it is a common condition. The unbalanced load happens in intermediate voltage network, low voltage network, and transformer. The occurrence of load imbalance in the distribution network is caused by one phase load which is not equal to each other. This is what causes loss or energy losses in low voltage networks as well as analyzing the effect of load balancing on the transformer against decreased power loss, i.e. the value of power loss before load balancing and after Load Balancing. This is examined in this final task, which is a load imbalance that occurs in the low voltage distribution network. The location selected in the research site of this final task is PT. PLN (Persero) Rayon Sedayu Jl. Wates KM 11 Argorejo Sedayu Yogyakarta. With these load imbalances resulted in a neutral current leak on the transformer. In principle, neutral currents are zero in balanced state. But in reality, a distribution system of electrical tension is always in an unbalanced load state. So in the 1 phase system as applied in Central Java and D.I. Yogyakarta, neutral current is approaching zero is considered to be good. The result of load balancing on the 6th of transformer distributions obtained average suppression of the power loss on neutral conductive is 242, 186 watts. Cost savings on financial losses after load balancing of Rp 171.409,563/month. So the goal is to do load balancing to reduce power losses, technical losses, and nontechnical losses.
      URI
      http://repository.umy.ac.id/handle/123456789/28723
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV