      ANALISIS PENGGUNAAN RELE DIFERENSIAL SEBAGAI PROTEKSI PADA TRANSFORMATOR DAYA 60 MVA GARDU INDUK KENTUNGAN

      Thumbnail
      View/Open
      COVER (110.5Kb)
      HALAMAN JUDUL (508.4Kb)
      HALAMAN PENGESAHAN (398.4Kb)
      ABSTRAK (35.25Kb)
      BAB I (52.37Kb)
      BAB II (542.7Kb)
      BAB III (106.4Kb)
      BAB IV (237.0Kb)
      BAB V (40.21Kb)
      DAFTAR PUSTAKA (89.39Kb)
      LAMPIRAN (937.3Kb)
      NASKAH PUBLIKASI (328.7Kb)
      Date
      2019-08-07
      Author
      KHUZAIMAH, RICKO MU’AMMAR
      Metadata
      Show full item record
      Abstract
      The electric power system consists of generation, transmission, and distribution components. In the process of conducting electrical energy in the transmission, disturbances can appear and one of them occurs on the power transformer. The protection system is needed to identification disturbances and decreases the damage problems by restricting the disturbed area. The protection of power transformers is using differential relays. The basic principle of this relay is Kirchoff's law where the inrush current equals the outflow. This study discusses comparing theoretical differential relay settings with the actual differential relay settings data on the Transformer IV 60 MVA Kentungan substation, also simulate it with ETAP 12.6 software. The method used by the writer is taking raw data by researching the 150-kV substation, after that all the component data are calculated manually and simulated with ETAP 12.6 software. The setting current based on theoretical calculations is 0.29 A, whereas the actual setting differential relay is 0.3 A. In the differential relay characteristic test, the differential current read on R and S phase is 0.342 A and 0.338 A in phase T. The differential relay will work if the currents that flow is greater than the current setting and if the disturbances occur in the safety area. After that, the relay will notify the circuit breaker to trip.
      URI
      http://repository.umy.ac.id/handle/123456789/28828
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV