View Item 
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Engineering
      • Department of Electrical Engineering
      • View Item
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Engineering
      • Department of Electrical Engineering
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      PENGEMBANGAN ANTARMUKA BERBASIS LABVIEW PADA ROKET MUATAN UNTUK KOMPETISI MUATAN ROKET INDONESIA 2019

      Thumbnail
      View/Open
      COVER (18.14Kb)
      HALAMAN JUDUL (702.6Kb)
      HALAMAN PENGESAHAN (204.8Kb)
      ABSTRAK (43.23Kb)
      BAB I (47.92Kb)
      BAB II (793.1Kb)
      BAB III (290.4Kb)
      BAB IV (418.7Kb)
      BAB V (15.36Kb)
      DAFTAR PUSTAKA (58.03Kb)
      LAMPIRAN (120.2Kb)
      NASKAH PUBLIKASI (2.310Mb)
      Date
      2019-03-28
      Author
      ANJASMARA, FUAD HAMMAMINATA ARYA
      Metadata
      Show full item record
      Abstract
      Universitas Muhammadiyah Yogyakarta as the one of the competitor in the Lapan’s competition, Komurindo 2019, have potentials to develop reliable interface for payload rocket. Designing process is in both ways, designing dummy data and interface. Designing dummy data is using Arduino UNO and Arduino IDE, while designing interface is using LabVIEW 2017. Arduino IDE gave command to Arduino UNO to produce dummy data so its data can be processed in LabVIEW 2017. Dummy data is produced from Analog 0 pin of Arduino UNO using randomSeed() code in Arduino IDE. Its format is determined as the research before. LabVIEW 2017 supporting data acqusition process and displaying result. Then, testing of data is in two methods, qualitative and quantitative. The qualitative method is trying to test the reliable of system. So, the quantitative method is trying to calculate the error of system in some system testing. From the simulation that was done, in result is system working reliable enough and 10 % error from 50 times data pickings. In 10 minutes, occurred three errors and not interfere LabVIEW process so LabVIEW is stop working. This matter is matched to the necessary of Komurindo 2019 team.
      URI
      http://repository.umy.ac.id/handle/123456789/28830
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV