View Item 
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Vocational Final Project
      • Elektromedik Engineering
      • View Item
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Vocational Final Project
      • Elektromedik Engineering
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      STERILISATOR UV DENGAN SISTEM REMOTE KONTROL BERBASIS MICROCONTROLLER ATMEGA328

      Thumbnail
      View/Open
      COVER (101.9Kb)
      HALAMAN JUDUL (262.3Kb)
      LEMBAR PENGESAHAN (345.6Kb)
      ABSTRAK (193.1Kb)
      BAB I (162.2Kb)
      BAB II (612.5Kb)
      BAB III (581.6Kb)
      BAB IV (451.8Kb)
      BAB V (144.7Kb)
      DAFTAR PUSTAKA (125.7Kb)
      LAMPIRAN (127.9Kb)
      NASKAH PUBLIKASI (631.3Kb)
      Date
      2019-07-15
      Author
      WALAN, WALAN
      Metadata
      Show full item record
      Abstract
      Hospitals as installation of medical services cannot be separated from the presence of a number of pathogenic microbes. The presence of these pathogenic microbes can cause nosocomial infections. In indonesa the data on the incidence of nosocomial infections is still rere, but it is estimated to be quite high considering the state of hospitals and general health is relatively not good. UV sterilization can help to kill germicidal numbers, if the device is connected to electrity, the power supply will provide voltage to each block that is on the module so that the buzzer and hourmeter will stop recording the uv lap life time. When retieving data with atime of 2 hours 20 times the average trial time is 7194 seconds, adeviation of 6 seconds, an error of 0,083%,a standard deviation of 37.842 seconds. For the seconds. For the seconds measurement, 4 hours 20 time the average time for 14395 seconds, a deviation of 4 seconds, an error 0,035%, a standard deviation of 29.105 seconds. For the third measurement 6 hours 20 time the average time for 21595 seconds, a deviation of 5 seconds, error 0,023%, standard deviation of 31.526 seconds.
      URI
      http://repository.umy.ac.id/handle/123456789/31092
      Collections
      • Elektromedik Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV