View Item 
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Engineering
      • Department of Electrical Engineering
      • View Item
      •   UMY Repository
      • 03. DISSERTATIONS AND THESIS
      • Students
      • Undergraduate Thesis
      • Faculty of Engineering
      • Department of Electrical Engineering
      • View Item
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      AUDIT ENERGI LISTRIK PADA GEDUNG E2 KAMPUS UNIVERSITAS MUHAMMADIYAH YOGYAKARTA

      Thumbnail
      View/Open
      COVER (96.45Kb)
      HALAMAN JUDUL (262.4Kb)
      LEMBAR PENGESAHAN (360.7Kb)
      ABSTRAK (183.3Kb)
      BAB I (197.4Kb)
      BAB II (767.4Kb)
      BAB III (215.5Kb)
      BAB IV (1.010Mb)
      BAB V (407.4Kb)
      DAFTAR PUSTAKA (288.9Kb)
      LAMPIRAN (642.8Kb)
      NASKAH PUBLIKASI (323.1Kb)
      Date
      2019-02-28
      Author
      PERMANA, REZA
      Metadata
      Show full item record
      Abstract
      Non-linear loads are one of the important factors that affect the quality of electric power to consumers. This load is a harmonic source that can reduce the quality of electric power. Non-linear load is generally a semiconductor component, where this load requires a current that is not fixed in the time period. UMY E2 building has a lot of energy saving equipment used such as LED lights, air conditioners (AC) that use VRF technology, computers and other electronic components which are included in non-linear load types. The research method used is a quantitative method. In this study, measurements were taken at the Sub Distribution Panel of E2 building and it was found that there was a maximum neutral current of 112.22 A due to unbalance, the value of Total Harmonic Distortion voltage on the R phase was 5.11%, the average S phase was 5.11 % and the T phase are on average 5.01%, and the value of the Total Harmonic Distortion of the minimum current in the R phase is 7.03%, the S phase is 6.25%, and the T phase is 6.75%. Voltage and current THD values do not comply with the IEEE 192-2014 standard. Based on the results of research and data analysis, to reduce harmonic planning is done to install a single tuned passive filter on E2 building
      URI
      http://repository.umy.ac.id/handle/123456789/32637
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV