Show simple item record

dc.contributor.advisorWIJAYA,NUR HUDHA
dc.contributor.advisorRAHMASARI,DESY
dc.contributor.authorSUTRIMO, SUTRIMO
dc.date.accessioned2017-09-28T03:31:33Z
dc.date.available2017-09-28T03:31:33Z
dc.date.issued2017-08-10
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/15132
dc.descriptionAlat ukur cahaya (lux meter) adalah alat yang digunakan untuk mengukur besarnya intensitas cahaya di suatu tempat. Besarnya intensitas cahaya ini perlu untuk diketahui, karena pada dasarnya manusia juga memerlukan penerangan yang cukup. lampu operasi yang baik harus memenuhi syarat yang sudah di tentukan berdasarkan undang-undang yang dikeluarkan oleh kemenkes, Pencahayaan yang cukup untuk kamar operasi 300-500 Lux dan untuk meja operasi adalah 10.000-20.000 Lux. Pengujian keakuratan hasil pengukuran pada alat ini, penulis membandingkan nilai intensitas cahaya alat penulis dengan nilai intensitas cahaya lux meter di Rumah Sakit PKU Gamping. Pengukuran data dilakukan sebanyak 20 kali pada jarak 1 meter dan 20 kali pada jarak 1,5 meter. Berdasarkan pengukuran dan perbandingan data dapat disimpulkan bahwa antara alat penulis dan pembanding memiliki error dan selisih yang relatif rendah, error yang didapat yaitu sebesar 0,01 % pada jarak 1 meter dengan selisih 2 lux, dan mengalami error sebesar 0,23 % pada jarak pengukuran 1,5 meter dengan selisih 24 lux. Untuk pengukuran jarak dan timer pada alat penulis didapat error 0 % dengan selisih 0 %en_US
dc.description.abstractLux meter is a tool used to measure the amount of light intensity in a place. The amount of light intensity needs to be known, because basically humans also need adequate lighting. A good operation lamp should qualify that has been specified based on laws that issued by kemenkes, Sufficient lighting for operating rooms is 300-500 Lux and for operating desk is 10,000-20,000 Lux. Testing the accuracy of the measurement results in this tool, the authors compare the value of light intensity of the authors tool with the value of light intensity using lux meter in Rumah Sakit PKU Gamping. Data measurements have been tested 20 times at a distance of 1 meter and 20 times at a distance of 1.5 meters. Based on the measurement and comparison of data, it can be concluded that between the author and comparator has the error and the difference is relatively low, the error that obtained is 0.01% at a distance of 1 meter by 2 lux difference, and an error of 0.23% at distance of 1.5 meters by 24 lux differences. For distance measurement and timer on authors tool obtained error 0% by 0% difference.en_US
dc.publisherD3 UMYen_US
dc.subjectlight, lux meter, distance and timer. Cahaya, Lux Meter, jarak dan timeren_US
dc.titleLUX METER DILENGKAPI SENSOR JARAK BERBASIS ARDUINO UNO R3en_US
dc.typeThesis T A VOK 060en_US