dc.descriptionPenelitian pengaruh beban pendinginan terhadap pengukuran koefisien perpindahan kalor evaporasi refrigeran R-134a di dalam saluran halus horizontal sangat penting untuk dilakukan karena dengan mengetahui beban pendinginan yang terdapat dalam suatu ruangan, seperti: jumlah penghuni, jumlah barang elektronik, dan juga waktu siang dan malam yang mempengaruhi variasi beban pendinginan terhadap mesin pendingin dimana kalor yang diserap evaporator dapat berubah. Perubahan kalor yang diserap evaporator ini diduga dipengaruhi oleh perubahan koefisien perpindahan kalor evaporasinya sehingga perlu diteliti. Metode yang digunakan pada penelitian ini adalah metode eksperimental dengan memvariasikan laju aliran massa air (cooling load) menuju evaporator dan juga mengatur frekuensi inverter untuk mengatur variasi laju aliran refrigeran. Dimana evaporator diletakkan di dalam suatu bak dengan ukuran 25 cm x 15 cm x 20 cm yang nantinya akan diisi air dan debitnya diukur menggunakan rotameter air. Pengujian dilakukan dengan menggunakan alat uji berupa sistem kompresi uap sederhana yang dimodifikasi dengan menambahkan heater, seksi uji, dan orifice. Dimana pada titik yang sudah ditentukan diletakkan pressure gauge dan termokopel untuk pengambilan data tekanan dan temperaturnya. Refrigeran yang digunakan adalah R-134a. Hasil penelitian ini menunjukkan bahwa nilai koefisien perpindahan kalor evaporasi naik dengan naiknya kapasitas beban pendinginan yang diberikan ke dalam evaporator, dengan ditambahkannya beban pendinginan (cooling load) per satu variasi laju aliran massa maka didapatkan nilai koefisien perpindahan kalor evaporasi (hevap) tertinggi yaitu 4273,5310 W/m2K pada variasi frekuensi inverter 24 Hz. Sedangkan nilai kapasitas beban pendinginan (cooling load) tertinggi yaitu 1043,86 Watt yaitu pada variasi frekuensi inverter 24 Hz. Sedangkan nilai koefisien perpindahan kalor evaporasi (hevap) terendah yaitu 940,834 W/m2K yaitu pada frekuensi 16 Hz, nilai kapasitas beban pendinginan (cooling load) terendah yaitu 410,622 Watt yaitu pada frekuensi 16 Hz.en_US
dc.description.abstractThe research of the influence of cooling load on the measurement of R-134a refrigerant evaporation heat transfer coefficient in horizontal fine channel is very important to do because by knowing the cooling load contained in a room, such as the number of occupants, the number of electronic goods, as well as the time of day and night Affect the variation of cooling load on the cooling machine where the heat absorbed by the evaporator may change. The heat changes absorbed by this evaporator are thought to be influenced by changes in the evaporative heat transfer coefficient so that it needs to be investigated. The method used in this study is an experimental method by varying the water mass flow rate (cooling load) to the evaporator and also set the frequency of the inverter to adjust the variation of refrigerant flow rate. Where the evaporator is placed in a tub with a size of 25 cm x 15 cm x 20 cm which will be filled with water and the debit is measured using a water rotameter. The test is done by using a simple vapor compression test modified by adding heater, test section, and orifice. Where at the point that has been determined put pressure gauge and thermocouple to take data pressure and temperature. The refrigerant used is R-134a. The results of this study indicate that the value of evaporative heat transfer coefficient increases with the increase of cooling load capacity given into the evaporator, with the added cooling load per one variation of the mass flow rate hence the highest hevap evaporative coefficient value is 4273, 5310 W / m2K at a frequency variation of 24 Hz inverter. While the value of the highest cooling load (cooling load) is 1043,86 Watt is the variation of frequency inverter 24 Hz. While the value of evaporative heating coefficient (hevap) is the lowest 940,834 W / m2K at 16 Hz frequency, the lowest cooling load capacity value is 410,622 Watt at 16 Hz frequency.en_US
dc.publisherFAKULTAS TEKNIK UMYen_US
dc.subjectHeat Transfer Coefficient, evaporation, cooling load, R-134a, Horizontal Smooth Koefisien Perpindahan Kalor, evaporasi, cooling load, R-134a, Saluran Halus Horizontalen_US
dc.titlePENGUKURAN KOEFISIEN PERPINDAHAN KALOR EVAPORASI RERIGERAN R-134a DI DALAM SALURAN HALUS HORIZONTAL DENGAN VARIASI KAPASITAS BEBAN PENDINGINANen_US
dc.typeThesis SKR F T 677en_US