Show simple item record

dc.contributor.authorNADJIB, MUHAMMAD
dc.date.accessioned2016-09-14T07:17:05Z
dc.date.available2016-09-14T07:17:05Z
dc.date.issued2014-07-16
dc.identifier.issn0854-8471
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/1877
dc.description.abstractThe fluctuation of solar radiation intensity caused fluctuate energy received by photovoltaic (PV) systems. Meanwhile, the electricity usage from PV systems is depending on a difference needs every time. These conditions can be influence on PV systems performance after use for some period. Currently, there are six of 50 Wp of standalone solar lighting systems (SLS) installed for cow-stable lighting purpose in Sleman, Yogyakarta. The aims of this research are to investigate the performance of SLS, especially in the solar modules and their batteries after one year period of operation. The physical conditions of all SLS’s component are checked. The load consumption time, the output voltage of solar module, and the battery voltage after charging and discharging are measured for each SLS. The data are used to analyze the average daily energy and the battery performance. Then the SLS which has the lowest performance is continued to investigate with maximum time loading. According to the test result, the physical conditions of SLS’s components are good but all of the components were dirty and the water in the batteries was low level. Overall, the SLS have been well-operated and the maximum DOD is 18.61%. Furthermore, the sixth SLS indicates that its battery have highest energy losses because the DOD is high, whereas the energy consumption, performance ratio, and battery efficiency are low. It appears that the basic problem is low maintenance. To maintain the SLS’s performance it needs to improve the quality of maintenance system.en_US
dc.publisherFAKULTAS TEKNIK UNIVERSITAS ANDALASen_US
dc.relation.ispartofseries21;2
dc.sourceteknika Vol. 21 No. 2Juli 2014
dc.subjectfotovoltaik, sistem penerangan tenaga surya, modul suryaen_US
dc.titleINVESTIGASI UNJUK KERJA SISTEM PENERANGAN TENAGA SURYA TIPE BERDIRI-SENDIRI SETELAH BEROPERASI SATU TAHUN DI SLEMAN, YOGYAKARTAen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • JURNAL
    Berisi tulisan dosen dalam yang telah dimuat dalam jurnal nasional maupun internasional yang tidak diterbitkan oleh UMY. Diharapkan menambahkan link dari jurnal yang asli dalam diskripsinya.maupun internasional

Show simple item record