dc.description | Stand pompa bahan bakar type in-line enam silinder dibuat sebagai media
praktik untuk memudahkan pemahaman saat dilaksanakan praktik. Karena
bentuk yang lebih sederhana dari bentuk aslinya. Disamping bentuk yang
disederhanakan namun tetap memiliki fungsi dan cara kerja yang sama.
Untuk mengidentifikasi kerusakan sistem penyalur bahan bakar pada fuel
inection pump dan nozzle dilakukan pembongkaran dan pengecekan
komponen. Setelah selesai dilakukan pengukuran menggunakan alat kalibrasi
tast dan nozzle tester, untuk mengetahui kerja dari fuel inection pump dan
nozzle.
Fuel inection pump yang sudah diuji menggunakan alat kalibrasi tast
dengan standar rpm 1.100, dan volume 11 cc – 14 cc. Begitu pula nozzle yang
sudah di uji menggunakan nozzle tester dengan standar tekanan 22 MPa / 3.200
psi. Dan hasil pengukuran fuel inection pump dan nozzle dapat bekerja normal
kembalistelah dilakukan perbaikan. | en_US |
dc.description.abstract | A fuel pump stand type in-line with six cylinders has been designed as a
practical media in order to improve understanding during practice. This design is
simpler than the original one that it enhances the practicality. In spite of its
simplicity, it still has the same function performance system.
To identify the damage of fuel channeling on the fuel injection pump and
nozzle, disassembly and verification process towards the component was
conducted. After that, the measurement using tast and nozzle tester calibrating
tool was implemented in order to figure out the performance of fuel injection
pump and nozzle.
The fuel injection pump was tested using tast calibrating tool with rpm
standard of 1.100 and 11 cc – 14 cc volume. Nozzle was also tested using nozzle
tester with 22 mpa / 3200 psi pressure standard. The fuel injection pump and
nozzle are working normally after improvement was implemented. | en_US |