dc.description | PLTU Sebalang menyuplai 2×100 MW yang dihasilkan dari dua unit penghasil listriknya yang diberi nama Unit 1 dan Unit 2. Total 200 MW listrik tersebut disuplai untuk membantu memenuhi kebutuhan listrik di wilayah Provinsi Lampung.. Sebagai sebuah pembangkit listrik yang beroperasi sesuai standar nasional dan internasional pastilah memiliki sistem gas buang. Sistem gas buang merupakan output dari proses pembakaran yang digunakan untuk mentransfer flue gas dari sisa hasil proses pembakaran di boiler menuju ke stack melalui pipa-pipa uap yang dibantu oleh beberapa peralatan penunjang. Salah satu peralatan penting penunjang sistem gas buang tersebut ialah Induced Draft Fan. Induced Draft Fan (ID Fan) merupakan sebuah kipas (fan) yang digunakan menghisap udara sisa hasil pembakaran (flue gas) dari dalam boiler keluar menuju stack. ID Fan berfungsi untuk mempertahankan pressure pada furnace boiler dan bekerja pada tekanan atmosfir rendah oleh karena itu tekanannya bernilai negatif. Besarnya volume flue gas yang dihisap oleh ID Fan diatur oleh besarnya persentase bukaan (sudut buka) damper yang dipasang di posisi sebelum ID Fan (inlet), semakin besar sudut bukanya maka volume flue gas yang dihisap ID Fan semakin besar. Besarnya bukaan inlet damper diatur oleh Motor Operated Valve (MOV), Sedangkan besarnya kecepatan putaran blades pitch ID Fan diatur oleh Variable Fluid Coupling (VFC) yang terhubung secara tidak langsung dengan motor penggerak ID Fan. Pengaruh ID Fan terhadap operasi sistem gas buang sangatlah vital, jika ID Fan tidak bekerja secara normal atau dapat dikatakan rusak, maka proses transfer flue gas ke stack tidak dapat terjadi dan akibatnya akan sangat fatal bagi operasional boiler maupun produksi energi listrik. Dalam kasus ini semua parameter data operasi ID Fan beserta motornya masih bekerja secara normal dan masih bekerja dibawah batas toleransi (sesuai standar), sehingga ID Fan beserta motornya dapat dikatakan dalam kondisi optimal. | en_US |
dc.description.abstract | PLTU Sebalang supplies 2x100 MW produced from two electricity generating units named Unit 1 and Unit 2. A total of 200 MW of electricity is supplied to assist electricity needs in Lampung Province. As a power plant that operates according to national and international standards must have a flue gas system. The exhaust gas system is the output of the process used to transfer gas to the pipeline process which can be assisted by some supporting equipment. One of the system supporting equipment is the exhaust gas. Induced Draft Fan (ID Fan) is a fan that sucks out the air from the flue gas from the boiler to the stack. ID Fan works to maintain the pressure on the boiler furnace and work in a low atmosphere because it is negative negative pressure. The amount of exhaust gas sucked by the ID Fan is regulated by the base percentage (open damper) of the damper installed in the position before the ID Fan (inlet), the larger the angle, the greater the volume of exhaust gas that is consumed by the ID Fan. The magnitude of the inlet damper opening by the Motor Operated Valve (MOV), while the speed of rotation of the ID Fan blade is displayed by Variable Fluid Coupling (VFC) which is connected directly with the ID Fan drive motor. The effect of ID Fan on the operation of the exhaust gas system is very vital, if the ID Fan does not work normally or can be said to be damaged, the process of transferring the flue gas to the stack cannot occur and the consequences will be very fatal for the operation of the boiler and the production of electrical energy. In this case all ID Fan operating data parameters can still work normally and still work according to standards, according to ID Fan and some of the motors that can be detected in optimal conditions | en_US |
dc.publisher | FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH YOGYAKARTA | en_US |
dc.subject | Air and Flue Gas Systems, MOV, VFC, ID Fa | en_US |
dc.title | PENGOPTIMALISASIAN KINERJA INDUCED DRAFT FAN DENGAN MENGATUR BUKAAN INLET DAMPER DAN BUKAAN VARIABLE FLUID COUPLING DI PLTU SEBALANG | en_US |