Show simple item record

dc.contributor.advisorZULFIAR, MUHAMMAD HERI
dc.contributor.authorWAHYUDI, ADILLAH
dc.date.accessioned2019-09-18T03:00:00Z
dc.date.available2019-09-18T03:00:00Z
dc.date.issued2019-03-26
dc.identifier.urihttp://repository.umy.ac.id/handle/123456789/28870
dc.descriptionKebakaran merupakan salah satu bencana yang sangat merugikan secara moril dan materil. Kebakaran dapat terjadi karena adanya nyala api yang tidak terkendali dan dapat menyebabkan kerusakan bangunan, kerugian secara materi dan jatuhnya korban jiwa. Penyebab terjadinya kebakaran gedung yang sering terjadi di Indonesia adalah korsleting alat elektronik, korsleting listrik bahkan kelalaian manusia. Sistem proteksi kebakaran pada bangunan merupakan salah satu upaya untuk meminimalisir terjadinya kebakaran yang besar dan meminimalisir kerugian yang diperoleh. Tujuan dari penelitian ini adalah untuk melakukan pemeriksaan serta penilaian perletakkan dan kelengkapan sarana sistem proteksi kebakaran pada Gedung Perkuliahan E6 dan E7 Universitas Muhammadiyah Yogyakarta, apakah sudah sesuai dengan peraturan terkait. Penelitian ini menggunakan acuan PD-T-11-2005-C dengan metode analisis observasi di lapangan. Hasil dari penelitian diperoleh nilai keandalan sistem keselamatan bangunan Gedung E6 dan E7 sebesar 85,65%. Nilai tersebut menunjukkan bahwa kelengkapan dan perletakkan sarana prasarana sistem proteksi pada Gedung E6 dan E7 Universitas Muhammadiyah Yogyakarta sudah baik dan sesuai dengan peraturan.en_US
dc.description.abstractThe purpose of this study was to explore and to assess the settlings and the completeness of fire protection system facilities at the E6 and E7 lecture buildings of Muhammadiyah University of Yogyakarta, whether they are in accordance with the relevant regulations or not. Fire is a disaster that causes moral and material loss which happens because of an uncontrollable flame. The causes of building fires that often occur in Indonesia are short circuits of electronic devices, electrical short circuits and even human negligence. Fire protection systems in buildings are one of the efforts to minimize the occurrence of large fires and to minimize the losses obtained. This study used the reference PD-T-11-2005-C with an observation analysis method in the field. The results of the study showed that the reliability value of the building safety systems of buildings E6 and E7 was 85.65%. This value indicates that the completeness and settlings of protection system infrastructure facilities in Building E6 and E7 of Muhammadiyah Yogyakarta University are good and in accordance with the regulations.en_US
dc.publisherFAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectBuilding. Lecture Building, Protection System, Fire.en_US
dc.titlePENILAIAN KEANDALAN SISTEM PROTEKSI KEBAKARAN PADA BANGUNAN GEDUNG PERKULIAHANen_US
dc.typeThesis SKR FT 438en_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record