dc.descriptionLatar Belakang: Karet elastik latek merupakan komponen alat aktif perawatan ortodonti cekat. pH, suhu serta peregangan kekuatan tarik merupakan salah satu faktor yang menyebabkan penurunan kekuatan tarik pada alat ortodonti cekat. Tujuan: Penelitian ini bertujuan untuk mengetahui pengaruh pH saliva terhadap kekuatan tarik elastik latek ortodonti ukuran 1/4inci 4,5oz. Metode: Desain penelitian ini adalah eksperimental laboratoris. 30 karet elastik latek ortodonti menjadi 3 kelompok, masing-masing kelompok terdiri dari 10 sampel. Karet elastik latek ortodonti dipasang pada jig board kemudian tiap kelompok direndam dalam saliva buatan pH asam, pH netral dan pH basa lalu dimasukkan kedalam inkubator selama 24 jam dengan suhu 37°C. Pengukuran dilakukan menggunakan Universal Testing Machine. Hasil penelitian diuji menggunakan uji Man Whitney dan uji Kruskal-Wallis. Hasil: Hasil menunjukkan perendaman pada pH saliva buatan terdapat perbedaan sebelum dan sesudah perlakuan. Hal ini menandakan terdapat pengaruh penurunan kekuatan tarik karet elastik latek (p<0,05). Uji Kruskal-Wallis menunjukkan perbedaan yang signifikan (p<0,05) pada perendaman pada semua pH. Kemudian dilanjutkan dengan analisis Mann-Whitney pada pH 7 dan 8 tidak terhadap perbedaan penurunan kekutan tarik. Sedangkan pH 5 dan 7 serta pH 5 dan 8 memiliki perbedaan signifikan. Kesimpulan : Terdapat pengaruh penurunan kekuatan tarik karet elastik latek ortodonti pada semua pH saliva buatan selama 24 jam, penurunan tertinggi terjadi pada pH 5 asam.en_US
dc.description.abstractBackground: Elastic latex rubber is a component of fixed orthodontic active appliance. pH, temperature and tensile strength are the factors that cause a decrease in tensile strength in fixed orthodontics appliance. Objective: The aim of this study was to determine the effect of salivay pH towards elastic latex strength orthodontic size of 1/4inchi 4.5oz. Method: The design of this study was an experimental laboratory. 30 orthodontic elastic bands into 3 groups, each group consisting of 10 samples. Elastic orthodontic rubber was installed on the jig board and then each group was immersed in acidic, neutral and alkaline saliva and then put into an incubator for 24 hours at 37°C. Measurements were made using Universal Testing Machine. The results of the study were tested using Man Whitney test and Kruskal-Wallis test. Results: The results showed immersion in artificial salivary pH, there were differences before and after the study which indicated an effect of decreasing the tensile strength of elastic latek rubber (p <0.05). The Kruskal-Wallis test showed a significant difference (p <0.05) on immersion at all. Followed by Mann-Whitney analysis at pH 7 and 8 was not have differences in decreasing tensile strength. While the pH of 5 and 7 and also pH 5 and 8 has a significant reduction effect. Conclusion: There is an effect of decreasing the tensile strength of orthodontic latex elastic rubber at all pH of artificial saliva for 24 hours, the highest decrease occurred at pH 5 acid.en_US
dc.publisherFAKULTAS KEDOKTERAN DAN ILMU KESEHATAN UNIVERSITAS MUHAMMADIYAH YOGYAKARTAen_US
dc.subjectorthodontic elastic rubber, tensile strength, pH of saliva.en_US
dc.titlePENGARUH pH SALIVA TERHADAP KEKUATAN TARIK ELASTIK LATEK ORTODONTI UKURAN ¼ inci 4,5ozen_US
dc.typeThesis SKR FKIK 502en_US