dc.description | Kebakaran merupakan suatu permasalahan yang tidak bisa lepas dari
manusia. Kerugian yang diakibatkan oleh kebakaran tidak hanya berupa kerusakan
bangunan saja, melainkan kerugian yang menyangkut moral dan jiwa manusia.
Pencegahan kebakaran pada bangunan gedung adalah mencegah terjadinya
kebakaran pada bangunan gedung atau ruang kerja dan ruang belajar. Penelitian ini
bertujuan mengetahui nilai tingkat keandalan dan penerapan sistem utilitas dan
pencegahan kebakaran pada gedung. Data sistem utilitas dan sistem pencegahan
kebakaran pada bangunan gedung dapat diketahui dan dilakukan dengan beberapa
metode diantaranya metode analisis pengamatan langsung dan penilaian sistem
utilitas dan pencegahan kebakaran pada gedung berdasarkan Peraturan Menteri PU
No. 26/PRT/M/2008. Hasil penelitian ini mendapatkan nilai keandalan sistem
utilitas pada bangunan E6 dan E7 (63,39%), Pascasarjana (62,33%), F3 (59,89%)
dan nilai keandalan sistem pencegahan kebakaran pada gedung E6 dan E7 (81,4%),
Pascasarjana (81,4%), dan F3 (52,31%). | en_US |
dc.description.abstract | Fire is a problem that can’t be separated from humans. The losses incurred
by fire are not only the destruction of the buildings, but the disadvantages of human
morals and souls. Fire prevention in buildings is to prevent the occurrence of fire
in buildings or workspace and study room. This study aims to determine the value
of reliability and application of utility systems and fire prevention in buildings.
Data of utility system and fire prevention system in buildings can be known and
done by several methods such as direct observation analysis method and
assessment of utility system and fire prevention in building based on Minister of
Public Works Regulation no. 26/PRT/M/2008. The results of this study obtained the
value of utility system reliability in buildings E6 and E7 (63,39%), Pascasarjana
(62,33%), F3 (59,89%) and reliability value of fire prevention system in buildings
E6 and E7 (81,4%), pascasarjana (81,4%), and F3 (52,31%). | en_US |
dc.publisher | FT UMY | en_US |
dc.subject | Utility, fire prevention, fire, buildings, field analysis method. Utilitas, pencegahan kebakaran, kebakaran, bangunan gedung, metode analisis lapangan | en_US |
dc.title | EVALUASI SISTEM UTILITAS DAN SISTEM PENCEGAHAN KEBAKARAN PADA BANGUNAN GEDUNG DI UNIVERSITAS MUHAMMADIYAH YOGYAKARTA | en_US |
dc.type | Thesis
SKR
F T
065 | en_US |