      ANALISIS PERHITUNGAN KAPASITOR BANK DAN HARMONIK DISTORSI PADA RUMAH SAKIT PANTI RAPIH YOGYAKARTA

      Thumbnail
      View/Open
      COVER (18.25Kb)
      HALAMAN JUDUL (797.8Kb)
      HALAMAN PENGESAHAN (311.4Kb)
      ABSTRAK (180.2Kb)
      BAB I (379.5Kb)
      BAB II (1.274Mb)
      BAB III (294.8Kb)
      BAB IV (1.033Mb)
      BAB V (183.9Kb)
      DAFTAR PUSTAKA (183.3Kb)
      LAMPIRAN (630.0Kb)
      NASKAH PUBLIKASI (627.2Kb)
      Date
      2019-01-12
      Author
      PUTRI, SEKARLITA GUSFAT
      Metadata
      Show full item record
      Abstract
      In case of distributing proper electrical power, Perusahaan Listrik Negara (PLN) have some policy to serve electrical service equally, and capable to supply all the need of consumers. From that matters, PLN will give sanction if power/capacity factor is under 0,85. The purpose of this sanction is to prevent energy wasted relentlessly. In this research, the main purpose is to analyze the calculation of capacity of capacitor to increase the power factor and also define active filter capacity to reduce harmonic in new building of Panti Rapih Hospital of Yogyakarta based on available load. This reaserch tried to fix the factor capacity in the newest building of Panti Rapih Hospital of Yogyakarta which previously was 0.73 became 0.9. the amount capasitor used was 450 kVAR, and was capable to minimise reactional capacity so then it can maximise the active capacity by simulating it with ETAP 12.6.0 software. Harmonical current which is resulted by an AC load is approximately 683. to reduce an impact that happens to Harmonical current from AC load is usinh a active filter with 720 A capacity. the purpose of using this 720 A capacity is to keep the electrical components from huge damage fue to gigantic Harmonical current.
      URI
      http://repository.umy.ac.id/handle/123456789/25786
      Collections
      • Department of Electrical Engineering

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV
       

       

      Browse

      All of UMY RepositoryCollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

      My Account

      Login

      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Theme by 
      @mire NV